TETRACTA · MODEL X-RAY
Model X-Ray Report
Two pinned artifacts compared under a fixed measurement contract
report schema rs-1.7validation pending
A · BEFORE
HuggingFaceTB/SmolLM2-1.7B-Instruct
@ 1dfd32118ef1
B · AFTER
motexture/SmolLCoder-1.7B-Instruct
@ d9b7eb7b380d
VALIDATION-PENDING DESCRIPTIVE RESULT — no calibrated risk or pass/fail grade
A response difference was observed under this exact contract.
The change is already present at the first evaluable position (output of decoder block 4 of 24); it may begin earlier, below the instrument floor, so no starting depth is reported for this pair.
Onset depth and extent are categorical and calibrated on controlled cells; this is not a magnitude or quality assessment.
A · SmolLM2-1.7B-Instruct B · SmolLCoder-1.7B-Instru FIXED CONTRACTsame probes · same conditions COMPARE24 probes evaluated OBSERVATION + DEPTHdifference observed schematic of the measurement path — no magnitude or raw statistics are drawn
difference_observed
yes
whether the instrument observed a response difference between A and B under the measurement contract
output_text_change_observed
yes
The recorded output text of A and B differs.
probes evaluated
24
size of the evaluated set at the reporting depth; this is not a count of probes that differed
pair relation
combined-artifact-change
recorded relation between the two artifacts under the pair contract; a combined-artifact change is not attributed to fine-tuning alone

Depth map — where the difference is observable

emb48121620finalEARLY · blocks 1–8MIDDLE · blocks 9–16LATE · blocks 17–24onset · at or before block 4
difference observedno difference observedbelow the instrument floor
Each cell is one profile position: emb is the embedding output, k is the output of decoder block k (blocks are numbered from 1), final is the output after the final normalization. Under this contract the change is already present at the first evaluable position (output of decoder block 4 of 24); it may begin earlier, below the instrument floor, so no starting depth is reported for this pair; every evaluable position differs (21 of 21): the change is not confined to one part of the network. Positions below the instrument floor (the embedding output and the outputs of blocks 1 to 3) cannot carry an onset. Cells are categorical: the map carries no magnitude, and once a position differs, later positions are expected to differ as well. Onset calibration for this instrument release (controlled in-memory lesions at known depths): exact onset predicted and observed in 6 of 6 controlled cells on each of three public models (Qwen2.5-0.5B-Instruct, SmolLM2-1.7B, TinyLlama-1.1B-Chat-v1.0); cross-board agreement on onset 4 of 4 cells.

What this means for you

MeasuredEvery evaluable position differs (21 of 21); under this contract the change is not confined to one part of the network. This is a record of what the instrument observed on a fixed set of inputs, not an assessment of the models.
Text outputOn the fixed input set, the recorded output text also differed.
Suggested next checksRun your own task set on A and B with identical inputs and generation settings, and compare the outputs pair by pair: this report says that a difference exists and where in the network it is observable under this measurement contract; only your own task set can say whether it matters for your use. The difference is present from the first evaluable position onward, so treat B as a different model rather than a variant of A: re-run your full evaluation set, and review the recorded configuration, tokenizer and generation differences above before attributing the change to weights. (guidance, not a measurement)

What differs between A and B (public metadata)

Configuration comparison from the artifacts' own public files — the two configurations are identical in the compared fields.

Numeric-precision fields are not compared here; any file difference is recorded in the artifact identity.

No difference recorded in the compared configuration fields.

Recorded pair relation: combined artifact change. No difference was recorded in the compared configuration fields, tokenizer or generation semantics summaries; no weights-only attribution is made.

Artifact facts and run conditions

Provenance

instrument releasexray_vg1
measurement contractmv-1.4 / paired-artifacts-2.0
report schemars-1.7
scan date (UTC)2026-09-07
card classRTX 5070 Ti
runtimePyTorch 2.11.0+cu128 · Transformers 5.10.1
operational receiptno attached to this standalone copy

Record identity: 95005d9d0b79 — the first 12 characters of the ordered-pair identifier, derived from the two artifacts and their revisions; a different pair, or the same pair at a different revision, yields a different identifier.
This document is a record of a measurement, not an opinion about the models: its fields are determined by the two public artifacts and the contract versions named above. In the null control for this instrument release, repeat scans on the same board class reproduced byte-identical recorded metrics.

Interpretation

This result records whether the frozen instrument observed a difference and, categorically, where it was observed. A difference is reported when any evaluated probe's response differs between A and B beyond the instrument's observation floor; the floor's value and the probe design are private. The depth map records the first position at which the difference was observed and the evaluable positions at which it was observed; both are categorical. It does not identify a cause, establish that weights were the only changed artifact, measure capability or quality, or authorize a shipping decision. Compare A to B only; do not compare numbers between reports.

What is shown and what stays proprietary

What this report shows
  • the verdict, and the recorded differences in configuration, tokenizer and generation settings
  • onset depth, the depth map and the extent of the observable difference (when enabled for the instrument release)
  • the output-text status, provenance, record identity and the operational receipt
What remains proprietary
  • probe design and probe text
  • the observation floor and thresholds
  • raw statistics, raw profiles, transformations and internal traces
  • sampling geometry and item-level records

The finding is yours; the instrument stays proprietary and is held fixed and versioned so that two reports produced under the same contract can be compared with each other. This standalone derivative carries no attestation; signing status is unavailable unless a separate signed receipt accompanies it.

Null-control reference for this instrument release: 0 of 16 A=B comparisons reported a difference (6 September 2026)
Version notice: produced under instrument release xray_vg1 with the contract versions shown above. Records produced under different contract versions are not interchangeable with this one, and earlier records may have been restated or withdrawn — see the correction record linked below.
Scope & Limitations: https://www.tetracta.ai/model-xray/scope/ · Correction record: https://www.tetracta.ai/model-xray/correction/
What this report does not do
Honesty box — scope and limits
This is a validation-pending descriptive measurement record, not a task-accuracy, safety, causal, deployment-readiness or regulatory result. Historical development findings used a superseded estimator and do not validate this release. The proprietary measurement recipe and raw evidence are intentionally withheld. Confirm decisions with task-specific evaluations on the exact deployed artifacts.
Tetracta · Model X-Ray · report schema rs-1.7 · this page contains no scripts and no numerical profile.